MPPT 20A 24V Solar Charge Controller
MPPT 20A 24V Solar Charge ControllerJUTA MPPT 20A20a MPPT solar controllers20a MPPT solar controllerMPPT 20A Solar panel charger regulatorMPPT 20A 12V Solar Charge Controller

MPPT 20A 12V 24V Solar Charge Controller MPPT-20 MPPT 20

CODE: MPPT-20

$54.00

In stock

Our quantity discounts:

Quantity  5+   10+   20+   50+ 
Price  $52.00   $50.50   $48.50   $47.00 

 

Feature:
The most outstanding feature of Maximum Power Point Tracking controller is intelligent tracking input voltage from solar panel, which could let solar panel always working at Maximum Power Point of V-A curve. Compared with normal solar charge controller, this MPPT controller could increase 10%-30% electrical power using efficiency from solar panel.

True MPPT,transformer coil inside.

 

mppt-10 solar controller,transformer oil inside

 

mppt-10 solar controller,transformer oil inside

 

mppt-10 solar controller,transformer oil inside

Function:
MPPT 10A solar charge controller regulator is not only have above mentioned special function, at the same time including completely Protecting and Controlling functions:
Overcharge protection Over-discharge protection Battery Reverse Current Protection Overloading Protection 
Short Circuit Protection Reverse Polarity Connection Protection

Package: 
1.1xMPPT 20A 12V 24V Solar Controller
2. 1x Users` manual

Thank you very much for selecting our product
This manual offers important information and suggestions with respect to installation, use and troubleshooting, etc. Please read this manual carefully before using the product and pay attention to the safety recommendations in it.

This MPPT controller is not only have above mentioned special function,at the same time including completely Protecting and Controlling functions:
Overcharge protection
Over discharge protection
Battery Reverse Current Protection
Overloading Protection
Short Circuit Protection
Reverse Polarity Connection Protection 

Model

MPPT-10

MPPT-20

Rated voltage

DC12V / 24V / 48V

Max current

10A

15A,20A,

No load loss

8mA/12V / 24V 30mA/48V

Voltage drop

300mV

Max voltage of solar panel

23V/12V23V×2/24V,23Vg×4/48V

Full charge cut

14V/12V,×2/24V,×4/48V25℃)

Low voltage cut

10.5V/12V,×2/24V,×4/48V

Reconnected voltage

12.6V/12V,×2/24V,×4/48V

Temperature compensation

-3mV/cell.

Efficiency

95%~97

Wire area

12A/m

Electrical power using efficiency

Can increase 1030

Net Weight

0.55Kg

0.65Kg

Dimension

188×93×55mm

188×118×55mm


 
Form a complete set:

Solar Panel: 12V solar system should use 40pcs cells laminated solar panel. The maximum power point voltage is over 18V. 24V solar system should use 2pcs above mentioned solar panels. 48V solar system should use 4pcs above mentioned solar panels.
Conductor: The cable between solar panel with MPPT solar charge controller should be better calculated by 1Ampere per 1mm2.
Solar Charge Controller: We have 12V, 24V and 48V three kinds of MPPT solar charge controllers with 10A, 20A, (other specifications could be designed as customer special request). Fit for power of solar panels:
MPPT-20—200Wp(12V), 40—400Wp(24V), 80-800Wp (48V).
  
Connection:

1.Connected the “+”, “-” poles of the battery to the controller (3, 4 from left) firmly and correctly. At this time the LOAD green LED is bright. If the LOAD green LED is not bright, it is indicate there is battery reverse polarity connection. Only LOAD green LED is bright, we could continue next step operation.
2.Connected the “+”, “-” poles of the solar panel to the controller (1,2 from the left) firmly and correctly.
3.Connected the “+”, “-” poles of the LOAD to
the controller (5,6 from the left) firmly and correctly.

Simply Measure Method:

For 12V system, measure the input voltage from solar panel with multimeter (terminal 1, 2 of controller), it is normal if the voltage of solar panel more than battery voltage 0.5-6V. Generally, the higher input voltage, the better charge efficiency. For 24v and 48V system, the input voltage will be much more higher than battery voltage
(Note: It is normal phenomenon the controller can not find Maximum Power Point within 10 minutes from system start.)

Indicator:

1.Load indicator, green, bright indicate there is output, Load could work, “off” indicate there is not output, and Load can not work.
2.Low Voltage Indicator, red; bright indicate the voltage of the battery is low. Load could not normal working. This is normal phenomenon. When the battery voltage recover to 12.6V or (25.2v), the Load will be automatically working, at this time the indicator is off.
3.Charge Indicator, red, bright indicate the battery need to charge, flickering means float charging, off means charge has stop.

RESET Button:

Please notice the rated current of your controller, if there is short circuit or overload happened, the MPPT controller will close output. (Load indicator off, Low voltage indicator off.)
If you need the MPPT controller recover work, please check the reasons and clear out the fault firstly. Then put a small stick such as toothpick, ball-pen tip inside the RESET hole, and press RESET button will be OK.

Attention:

1.Please check the rated voltage of the solar panel, battery, and load are all the same with 12V or 24V or 48V.
2.Please pay attention to connection, do not connect the “+” “-” poles of solar panels and loads wrong.( Wrong connection will be burn your MPPT controller)
3.Battery must be connected earlier than solar panels and load. When take off the system, Solar Panels must be take down first, then cut off battery.

  

 

 

Type the characters you see in the picture above.