EPTECH 300W Power Frequency Pure Sine Wave Inverter 24VDC to 220VAC SPWM Technology Switched Output Voltage and FrequencyEPTECH 300W Power Frequency Pure Sine Wave Inverter 24VDC to 220VAC SPWM Technology Switched Output Voltage and FrequencyEPTECH 300W Power Frequency Pure Sine Wave Inverter 24VDC to 220VAC SPWM Technology Switched Output Voltage and FrequencyEPTECH 300W Power Frequency Pure Sine Wave Inverter 24VDC to 220VAC SPWM Technology Switched Output Voltage and FrequencyEPTECH 300W Power Frequency Pure Sine Wave Inverter 24VDC to 220VAC SPWM Technology Switched Output Voltage and Frequency

EPever STI-300 300W 24VDC-220VAC Pure Sine Wave Inverter

CODE: STI 300-24-220

$107.46

In stock

Our quantity discounts:

Quantity  10+   20+   50+ 
Price  $107.46   $102.99   $100.00 

EPTECH 300W Power Frequency Pure Sine Wave Inverter 24VDC to 220VAC SPWM Technology Switched Output Voltage and Frequency

IMG_3128IMG_3131IMG_3133

 

Introduction

Thanks for purchasing our company’s inverter of STI series. The product is a sine wave power frequency inverter 

which can convert 12V DC to 220V AC 50Hz based on full digital and intelligent design. It features high reliability,

 high efficiency, concise outline, small volume, full protection functions, easy installation and operation.

 The inverter can be aplied in many fields especially for solar photovoltaic power system.

 Complete isolation-type inverter technology, noiseless sine AC voltage of output

 Adoption of advanced SPWM technology, pure sine wave output

 Dynamic current loop control technology to ensure inverter reliable operation

 Saving mode for selection

 Wide DC input voltage range

 Excellent EMC design

 Low output harmonic distortion(THD≤3%)

 LED indicators for input voltage range, load power range, normal output & failure state

 Input polarities conversed, load short-circuit, overload, under/over input voltage and over-temperature

 protections and alarms, inverter’s inner fault protections

 Fitted for many kinds of AC loads such as household appliances, electric tools and industrial devices

Wide working 

temperature range (industrial level)

Mechanical Drawings

Important Safety Instructions

As an AC power supply equipment, the inverter’s output voltage is with the same level as that of household power plug.

 Mind the AC output terminals, or you may get an electric shock!

Attentions:

 Connect the DC input according strictly to the requirement. The power inverter has a relatively wide input range,

 but too high or too low input may cause problems even destroy the inverter. 

 Do not expose the inverter to humid, flammable, explosive or dust environment. Do not install the inverter in airproof 

location and keep enough space around the inverter.

 Inverter input is recommended to connect to battery. If for testing purpose, user should select DC power supply current 

at least twice greater than that of the inverter rated input to keep inverter normal operation.

 Make sure the air ventilation clearance around the inverter is more than 10cm, for when the inverter works continuously

 its surface may became very hot. Keep away from the material or device which may suffer from 

high temperature when the inverter is working.

 Connect the load devices to the AC output outlet or terminals, then the DC input. Make sure both the input 

and output connects are correct, switch on the inverter first and then turn on the load.

 Do not connect the battery charger or similar devices to the input terminal of the inverter. 

 Do not put the inverter close to the open lead-acid battery because the sparkle in the terminals may 

ignite the hydrogen released by the battery.

 Do not attempt to repair the fault inverter yourself, otherwise it may lead to a serious accident. 

Please connect the manufacture’s engineer.

Inverter Operation

Connect the input and output terminals accurately by referring to the previous chapter. Use the ON / OFF switch 

on the front panel to turn the power on. Turn AC loads on one by one after the output of the inverter is normal,

 in order to prevent protections resulted from the surge power.

 Set the power switch to the ‘OFF’ position.

 Insert the load’s plug into the inverter’s output outlet, or cables to the output terminals.

 Connect the battery (‘+’ terminal with red line, ‘-’with black line). Do not connect them by contraries, 

or it will damage the power inverter.

 Switch the inverter to ON and then turn the loads on one by one. Check the operation state of both power inverter and loads.

 ‘Green’ of the LED indicator means the state is normal. 

 If there are different loads, it is suggested that turn on the load with large startup current first, such as television,

 then turn on the load such as lamp when the inverter works stable.

 If the failure LED indicator is ‘Red’ and the buzzer alarms or no output when you turn on devices, 

switch off the loads and power inverter immediately. Check the system by referring to the troubleshooting guide.

 Turn on the devices again according to the operation methods after the failure is removed.

 Input Level: Display Input Voltages

LED Status

Input Voltage

RED Slow Blink

<10.5V

RED

10.5~11 V

ORANGE

11~12 V

GREEN

12~14.5V

  ORANGE Fast Blink

14.5~16 V

RED Fast Blink

>16 V

 Load Level: Display AC Loads

LED Status

AC Load

ORANGE

<60 VA

GREEN

60VA~225 VA

RED

>225 VA

RED Slow Blink

Overload

RED Fast Blink

Short Circuit

 Output & Fault Status

LED Status

Status

GREEN

Output Ok

RED Fast Blink

Overload or Short circuit, Output Off

RED Slow Blink

Over or Low input voltage, Output Off

ORANGE Fast Blink

Over temperature, Output Off

RED

Inverter Fault, Output Off

OFF

Power Off,Output Off

 

 

 Alarms

Alarms

Status

Buzzer Sounds

Overload or Short circuit, Output Off

Over or Low input voltage, Output Off

Over temperature, Output Off

Inverter Fault, Output Off

 

 

echnical Specification

DC Input

Input Rated Voltage

12V

Input Voltage Range

10.5 ~ 16VDC

No-Load Power

≤5W

AC Output

Output Voltage

AC 220V±3%

Rated Power

≥240W

Maximum Short Time Power 

450VA; 10s

Surge Power

600VA; 1.5s

Output Mode

Single phase

Output Waveform

Sine wave

Frequency

50±0.5% Hz

Output Waveform Distortion 

THD≤ 3%

Efficiency at Rated Power

≥81%

Mechanical Parameters

Exterior(L*W*H mm)

314.5×166×100.8

Installation(L*W mm)

200×154

Hole Size(mm)

R4

Net weight (kg)

5.3

 

Environmental Parameters

Working Temperature

-20 °C ~+50 °C 

Storage Temperature

-35 °C ~ +70 °C 

Humidity

< 95%(N.C.)

Altitude

< 5000 m (Derating to operate according to IEC62040 at a height exceeding 1000 m)

Others

Insulation Resistance

Between DC input terminals and metal case: ≥550MΩ;

Between AC output terminals and metal case: ≥550MΩ.

Dielectric Strength

Between DC input terminals and metal case: 

Test voltage AC1500V, 1 minute

Between AC output terminals and metal case: 

Test voltage AC1500V, 1 minute

 

 