Share this product
|
Description
CMP110 (60A-11A) solar charge controller is controlled by CPU, According to the voltage of battery; controller will adjust the charge current and decide if to supply the loads electricity. The following is the detailed performance:
1.Generally keep the battery on full voltage condition.
2.Prevent the battery from over-charging.
3.Prevent the battery from over-discharging.
4.Prevent supplying electricity from the battery to solar panels during nights.
5.Reverse Polarity Protection for Battery
6.Reverse Polarity Protection for Solar panels
7.When the current of load exceeds the rated one of controller, the controller will turn into the self-protection state and is automatically locked up, the screen shows “Overload”.
8.Short Circuit happens; The Controller will turn into the self-protection state and is locked up, the screen show “Short circuit”.
9.Low voltage happens to battery, the controller will automatically separate loads from system. When the voltage of battery goes up, the loads will automatically restart to work.
10.Protection from the lightning strike
11.When Controller is normally working, the LCD Screen will show New Charging Current (a dash“-”before the numeral), Discharging Current and Voltage of battery every 5 seconds.
12.Controller is always counting Charging Current Hours and Discharging Current Hours of the Battery
13.When controller start up, according to the voltage level of battery, Controller will self-setup the Charging-off voltage, the Load-off voltage, the Load-on voltage. These datum is tacitly approved under the standard environment temperature 25℃.
14.According to varies system temperature, the controller will automatically compensate the temperature of the charging voltage.
15.Users could setup the Charge-on or off voltage, the load-off voltage, the Load-on voltage, etc, according to their requirements.
16.To prevent battery from over discharging, Controller will automatically control the lowest Load-off voltage of the load, which is no less than 10V (as per 12V battery) or 20V (as per 24V battery). If voltage of the battery is less than 10V (or 20V), the button “-” will stop working.
17.To recover its defaults, please keep pressing down the button “Menu” for over 5 seconds.
1.Generally keep the battery on full voltage condition.
2.Prevent the battery from over-charging.
3.Prevent the battery from over-discharging.
4.Prevent supplying electricity from the battery to solar panels during nights.
5.Reverse Polarity Protection for Battery
6.Reverse Polarity Protection for Solar panels
7.When the current of load exceeds the rated one of controller, the controller will turn into the self-protection state and is automatically locked up, the screen shows “Overload”.
8.Short Circuit happens; The Controller will turn into the self-protection state and is locked up, the screen show “Short circuit”.
9.Low voltage happens to battery, the controller will automatically separate loads from system. When the voltage of battery goes up, the loads will automatically restart to work.
10.Protection from the lightning strike
11.When Controller is normally working, the LCD Screen will show New Charging Current (a dash“-”before the numeral), Discharging Current and Voltage of battery every 5 seconds.
12.Controller is always counting Charging Current Hours and Discharging Current Hours of the Battery
13.When controller start up, according to the voltage level of battery, Controller will self-setup the Charging-off voltage, the Load-off voltage, the Load-on voltage. These datum is tacitly approved under the standard environment temperature 25℃.
14.According to varies system temperature, the controller will automatically compensate the temperature of the charging voltage.
15.Users could setup the Charge-on or off voltage, the load-off voltage, the Load-on voltage, etc, according to their requirements.
16.To prevent battery from over discharging, Controller will automatically control the lowest Load-off voltage of the load, which is no less than 10V (as per 12V battery) or 20V (as per 24V battery). If voltage of the battery is less than 10V (or 20V), the button “-” will stop working.
17.To recover its defaults, please keep pressing down the button “Menu” for over 5 seconds.
Data Sheet
Type |
CMP110 |
|
Rated voltage |
48V |
|
Maximum loading current |
50A——110A |
|
Load off voltage |
42V Recognize tacitly、rest |
|
Charge off voltage |
54.8V Recognize tacitly、rest |
|
Resumed voltage of boot-strap |
50.4V Recognize tacitly、rest |
|
Temperature compensation |
-3mv/cell. |
|
Unloaded waste |
≤60mA |
|
Minimum area of connection |
25m㎡ |
|
Loop voltage drop |
<600mv |
▲environmental temperature : < 25℃
Facebook comments
Find us on Facebook
Attachments
User Manual (Juta_CMP110_User_Manual.pdf, 208 Kb) [Download]
Tags
You may also like
Reviews
No posts found
New post
Send to friend
Hot Goods
Tag Cloud
Amplifier
Amplifier Simulator
Amps
Chromatic Tuner
CM3024Z
CM5024Z
CMP12
CMP24
CMP45
Dehumidifier
EPIP20-DB
EQ
Guitar Effect Pedal
Guitar Tuner
Household Dehumidifier
inverter
ipad 2
JMT-9009B
JT-12B
Meter
Metro-tuner
Metronome
MPPT
MPPT-30
MPPT 30A
smart cover
solar charge controller
solar panel
Tone Generator
TRACER1206
TRACER1210
TRACER1215
Tuner
wireless EQ
|
Join our community :
|
We Ship Worldwide: United States | Italy | United Kingdom | France | Germeny | Sweden | Japan | Canada | Australia | New Zeland | Greece
Hot Products : Solar Controller | Solar Charge Controller | MPPT | MPPT Controller | MPPT Solar Charge Controller | Guitar Tuner | Mini Guitar Tuner | Clip-on Tuner | Guitar Metro-Tuner | Mini Amplifier | Guitar Effect Pedal